|
| |||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||||||||||||
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||
|
Providing complete Electrical, Instrumentation and Control Engineering
Details with Drawings, Equipment specifications, procurement, Inspection,
Erection Supervision, Testing, Commissioning Troubleshooting & efficient
running of Plant & Machinery etc. to individual client requirements.
Energy Audit, Locating energy wastage points, monitoring energy
utilization. Reducing energy costs. Monitoring plant maintenance, machine
availability, spares inventory control. Machine life expectancy and
replacement scheduling.
Complete execution of PLC-PC Automation systems, preparing Logic charts,
Ladder Diagrams, P&I drawings, Hard and Soft Mimics, Field controllers,
Remote 10 Terminals etc. Providing end to end solutions. Remote operation
of Plant and Machinery, Building Automation.
Aquiring data from PLC & Field equipment. Providing supervisory control,
processing aquired data. Generating Alarms & Events Logs, Graphic software
Mimics of Plant Showing current status of Machines and allowing remote
operation by PC from anywhere. HMI/HMI (Man Machine interface), GUI (Graphic
User interface) terminals.
Switchboards, Distribution Panels, MCC, PCC, LT Panels, Control Desks,
Mimic, PLC & IO Panels, Interface Relays, LCC’s etc.
Protection & Control Relays for Automatic Power Factor Correction, Earth
Fault, Over-current, Short Circuit Protection. Interposing Relays for I/O
circuits of PLC, Master Trip Relays.
|
Home > Relays > Earth Leakage Relay
RELAYS
Earth Leakage Relay with CBCT - CIT11 (Residual Current Relay) Operation In an earthed neutral A.C. System the sum total of phase and neutral current is zero i.e. there is no leakage current. However, if at any place a failure of insulation takes place then part of the phase current returns via earth instead of neutral. The active and neutral currents are then no longer equal. This unbalance is detected by a core balance current transformer for onward tripping of circuit breaker. Construction This protection system basically comprises of two components : CBCT - Core Balance Current Transformer : This is supplied in ring or rectangular shape to suite mounting on conductors/cables or busbars/circuit breaker. RELAY : The Information from C.B.C.T. is first of all amplified by the amplifier stage from there it is devalued and only when the leakage exceeds the preset value it operates a relay. Setting
|
Hybrid Automation Systems
Highly dependable Automation systems with standby conventional manual
controls. Specially designed for industries where skilled technicians are
not available. Recipe Control & Batch Operations Operating Plant & Machinery to produce specified quality of products to
selected recipes. Preventing human errors. Controlling Blending, Dosing and
process operations.
End to End solutions from inception to Economic operation of industry.
Building and Hotel Automation enhancing comfort at lower costs. Turnkey
execution of Electrification and Automation control projects, including
design, engineering, providing man and materials, monitoring, testing and
commissioning, production and economy control of the systems.
Direct acquisition (DAQ & DCS) of production, operation, instrumentation,
alarm & events data from machines and field instruments. Storing and
processing aquired data, generating production and economy statements and
reports. Logging and monitoring violation of set values. Software Engineering Custom
Built commercial & Technical Software for enhancing and optimization of
Business, including inventory control, cost analysis data, quality control
etc. Web Services ![]() Website design & development, updating & renovation, free hosting, domain registration, website promotion & marketing, free consultation, multimedia services, e-commerce solutions, database development, internet solutions Read More |
|||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||
|
| |||||||||||||||||||||||||||||||||||||||||||||||||